UM 45/UMP 45/UMPC 45 - Oil Service Units

With UM 45/UMP 45/UMPC 45 hydraulic and lubrication systems can be filled, cleaned or fluid can be pumped over without using the filter function.
UM 45/UMP 45/UMPC 45 are delivered equipped with hoses
UMP 45 is equipped with adapters for PODS Pro
UMPC 45 with integrated particle monitor to supervise oil cleanliness during the filtering process
The filter element can be removed from the housing together with the cover
On the bottom of the from inside to outside flown through filter element there is a dirt retention valve. The dirt retention valve ensures that solid particle sediment is completely removed with the filter element and eliminates the need for flushing the filter housing
Longer service intervals und higher machine availability

Hydraulic fluids Mineral oil and biodegradable fluids (other fluids on request)
Temperature range of fluids 0°C - +60°C
Hydraulic connection Suction hose NG 32, 2.7 m long with lance, with strainer 280µm; pressure hose NG 25, 2.7 m long with lance
Ambient temperature range 0°C - +50°C
Tank capacity approx. 13 l

 

Operating position upright
Pump design Internal gear pump
Suction height maximal 2.0 m
Clogging indicator optical


UM(P) 45-1553 UM(P) 45-4553 UM(P) 45-1153
Nominal flow rate 45 l/min* 45 l/min* 45 l/min*
Filter fineness 3EN2 ß3(C)=200 3EN2 ß3(C)=200 5EN2 ß5(C)=200
Dirt capacity Mi at Q 1950 g 1950 g 1980 g
Operating voltage 1 ~ 230 V 3 ~ 400 V 50 Hz
3 ~ 460 V 60 Hz
1 ~ 230 V
Operating frequency max. 50/60 Hz 50/60 HZ 50/60 Hz
Motor power 1,1 kW* 1,1 kW* 1,1 kW*
Viscosity continuous operation min. 15 mm²/s 15 mm²/s 15 mm²/s
Viscosity continuous operation max. 600 mm²/s 600 mm²/s 600 mm²/s
Viscosity short-term operation max. 800 mm²/s 800 mm²/s 800 mm²/s
Operating pressure max. 7 bar 7 bar 7 bar
Weight 76,5 kg (84 kg**) 76,5 kg (84 kg**) 76,5 kg (84 kg**)
Replacement element V 7.1560-103 V 7.1560-103 V 7.1560-03
*Indications at 50 Hz. **Weight without PODS Pro

 

 

UMPC 45-15535 UMPC 45-45535
Interface RS 232 RS 232
Data volume 500 measurements 500 measurements
Nominal flow rate 45 l/min* 45 l/min*
Filter fineness 3EN2 ß3(C)=200 3EN2 ß3(C)=200
Dirt capacity Mi at Q 1950 g 1950 g
Operating voltage 1 ~ 230 V 3 ~ 400 V 50 Hz
3 ~ 460 V 60 Hz
Operating frequency max. 50/60 Hz 50/60 HZ
Motor power 1,1 kW* 1,1 kW*
Viscosity continuous operation min. 15 mm²/s 15 mm²/s
Viscosity continuous operation max. 600 mm²/s*** 600 mm²/s***
Viscosity short-term operation max. 800 mm²/s 800 mm²/s
Weight 97 kg 97 kg
Replacement element V 7.1560-103 V 7.1560-103
*Indications at 50 Hz. ***the exact determination of the cleanliness class is possible within a viscosity range of 15 mm²/s to 250 mm²/s.


  •  
    SF item
    Type
    Note
  • SF item UM 45-1553
    TypeFilter service unit
    Noteoil service unit - fineness 3EN2 - operating voltage/-frequency 1~230 V / 50/60 Hz
  • SF item UM 45-4553
    TypeFilter service unit
    Noteoil service unit - fineness 3EN2 - operating voltage/-frequency 3~400 V / 50 Hz - 3~460 V / 60 Hz
  • SF item UM 45-1153
    TypeFilter service unit
    Noteoil service unit - fineness 5EN2 - operating voltage/-frequency 1~230 V / 50/60 Hz
  • SF item UMP 45-1553
    TypeFilter service unit
    Noteoil service unit with adapter for PODS Pro - fineness 3EN2 - operating voltage/-frequency 1~230 V / 50/60 Hz
  • SF item UMP 45-4553
    TypeFilter service unit
    Noteoil service unit with adapter for PODS Pro - fineness 3EN2 - operating voltage/-frequency 3~400 V 50 Hz - 3~460 V 60 Hz
  • SF item UMP 45-1153
    TypeFilter service unit
    Noteoil service unit with adapter for PODS Pro - fineness 5EN2 - operating voltage/-frequency 1~230 V / 50/60 Hz
  • SF item UMPC 45-15535
    TypeFilter service unit
    Noteoil service unit with integrated particle monitor - fineness 3EN2 - operating voltage/-frequency 1~230 V / 50/60 Hz
  • SF item UMPC 45-45535
    TypeFilter service unit
    Noteoil service unit with integrated particle monitor - fineness 3EN2 - operating voltage/-frequency 3~400 V / 50 Hz - 3~460 V / 60 Hz
  • SF item V 7.1560-103
    TypeHydraulic filter
    Notereplacement element UM 45-1553 and -4553 - UMP 45-1553 and -4553 - UMPC 45-15535 and -45535 - fineness 3EN2
  • SF item V 7.1560-03
    TypeHydraulic filter
    Notereplacement element UM 45-1153 - UMP 45-1153 - fineness 5EN2
  • SF item V 7.1560-06
    TypeHydraulic filter
    Notereplacement element - fineness 10EX2
  • SF item Y 7.1560-05
    TypeHydraulic filter
    Notereplacement element water-absorbing - fineness 8E-A
  • SF item S 9.0417-13
    TypeHydraulic filter
    Notepump protect filter - fineness 280 micron
  • SF item DG 042-04
    TypeSoiling indicator
    Noteopticaldifferential pressure indicator

Any questions? We are at your service!

Do you have any questions regarding our products or would you like a personal advice? No problem, contact us directly.
We'll be pleased to help you!

  • info.ch@sf-filter.com
  • +41 44 864 10 60
  • SF-Filter AG, Kasernenstrasse 6, CH-8184 Bachenbülach